Air Testing Solutions
Air Sampling Instructions
- Tape lift samples are collected using 10 cm tape, folded at edges for avoiding any contamination. The tape is pressed once on the tested surface.
- The samples will be submitted in sealed plastic bags
- All samples should be clearly identified/ numbered
Method of Air Testing
- All analyses are performed using transmitted polarized light microscopy (size of analyzed particles > 1 um).
- Microscopic identification of particles present in dust deposited on various surfaces
- Dust particle counting on air filters by digital imaging
- Identification of mineral grains and rock fragments, biological materials, natural and processed fibers, soot, carbonized materials, etc